Air quality is always an issue for woodworkers, especially if we are working in a basement or when we don’t want to give up the heat in the shop to an open window during those cold winter months. There are plenty of ‘store bought’ systems out there to filter the air, but they can be pricey. So for those of us who would rather spend the money on another router or just like to make ‘stuff’, I have a suggestion (Photo 1).
Build a box, cut a big hole in the bottom and install an exhaust fan in it (Photo 2). Then cover the hole with a couple of disposable furnace filters and cut slots in the bottom of the box to vent the filtered air back into the room (Photo 1).
Note: follow all local building and electrical codes when making, wiring and installing the system (Photo 3).
Now would be a good time to discuss a little air flow math: My fan is rated at 1000 CFM in 1600 sq ft of attic space, (cubic feet per minute) – that is how much air the fan will move in a minute. My shop/garage is 22′ x 22′ x 10′ = 4,840 cubic feet, 484 sq ft. So if my math is right, my fan should exchange the air in my shop in about 4 to 5 minutes. That sounds good to me.
I installed mine between the trusses in the attic, (Photos 4a and 4b) only the filters and vent deflectors protrude into the room (Photo 5). If you don’t have an attic, (or your mate won’t let you cut a hole up into the kitchen floor), just mount the box on the ceiling.
My garage trusses are 24″ on center, so I was able to use a 15″. fan. The box measures 31″. x 22″. x 12″. high, (Photo 6a and 6b), and the base that mounts to the ceiling measures 32″. x 27″. I was then able to span the trusses and leave extra room for the vent slots.
I used 2 filters to get better filtration, (Photo 7). I just replace the bottom one when it gets clogged and put a new one on top.
Notice the low profile of the finished air filter in my garage. Good luck and breath deeply.
Photos By Author
Jake is a registered member of WWGOA. See more of Jake’s woodwork at his website, Saw Dust by Jake.
Submit your favorite woodworking tip or technique to editor@wwgoa.com and you could earn $100 if we publish your idea.
16ftx24ft woodworking shop
does it vent right into the attic or outside?
Your design looks as if the air from the work space is being sent outside and not back into the work space. In this case, the filters don't provide any value to what you are breathing inside. In hot/cold climates, the cool/warm area is being sent outside increasing your cooling/heating bill. Also although the fan maybe rated at 1000 cfm, your design reduces this number, because of how close the top of the hood is to the fan and then has to may a 90 degree turn. In other words, the area flow is being pressed against the hood, stops and then moves towards the exit. My guess is that the design probably is working at 50 - 75% efficiency.
Hell of an Idea brother !! I Like it !! May have to "Copy" that...... Thanks dude !
Do you sell the airfiltratiom system plan .
Looks good!. If you know a heating contractor, you might see if they have any old furnace blower assemblies they want to get rid of. They would be free (cutting your costs) and, if serviced regularly, would provide years of service. Also use Pleated filters rather than the cheap disposable ones. They are more expensive but will capture more dust too! Especially if you're recycling your air.
To what particle size are you filtering? 10 microns, 5 microns? To what particle size is enough? Thx, and I love the low profile aspect..